Tomey OA-2000 Optical Biometer

$2,700.00

Tomey oa-2000 Optical Biometer provides non-contact, noninvasive, automated measurement of axial length (AL), anterior chamber depth (ACD), lens thickness, and central corneal thickness (CCT) based on Fourier-domain technology plus Placido-disc–established corneal topography, based company literature.1,2 It provides improved usability, connects remotely to an ultrasound biometric unit for hard-to-read eyes, provides one-shot IOL power calculation, and supplies an internal database for storage.

Category: Tag:

Description

Tomey OA-2000 Optical Biometer

Tomey OA-2000 Optical Biometer is the perfect instrument for measuring axial length, the corneal curvature radius, corneal topography, and more in a single shot. High penetration capability is available using the Fourier domain method, which enables high speed scans.

Tomey Optical Biometer OA-2000 integrates topography, axial length, lens thickness and pachymetry which yield perfect data set for ray tracing. This assures best results even in exceptional eye conditions or Toric IOL calculation. Starting with topography, pachymetry, ACD and lens thickness followed by axial length, pupil diameter and white to white – this guarantees an enhanced usability in terms of IOL power calculation.

By simply touching the center of the pupil on the monitor the measurement starts immediately. Due to our well known 3D eye tracking technology all relevant data are captured quickly, even with uncooperative patients. Starting with topography, pachymetry, ACD and lens thickness followed by axial length, pupil diameter and white to white – this guarantees an enhanced usability in terms of IOL power calculation.

The OA-2000 integrates topography, axial length, lens thickness and pachymetry which yield perfect data set for ray tracing. This assures best results even in exceptional eye conditions or Toric IOL calculation.

Tomey oa-2000 FEATURES:

IOL Ray Tracing Calculation
Axial length
ACD & LENS thickness
Topography Keratometer
All measurements – simply one touch
Pachymetry
White to White
Pupil diameter

SPECIFICATIONS

Measurement range
Axial length 14 – 40mm
Anterior chamber depth 1.5 – 7.0mm
Crystalline lens thickness 0.5 – 6.0mm
Corneal thickness 0.2 – 1.2mm
Corneal curvature radius 5.0 – 11mm
Pupil diameter 1.5 – 13mm
Corneal diameter 7 – 16mm

Measurement accuracy
Axial length ±0.03mm
Anterior chamber depth ±0.05mm
Crystalline lens thickness ±0.05mm
Corneal thickness ±5μm
Corneal curvature radius ±0.02mm(

Software

Biometer
Topography-Keratometer
Pachymeter
Pupillometer
Axial length
ACD & LENS thickness
White to White
IOL Ray Tracing Calculation by OKULIX (optional)

Reviews

There are no reviews yet.

Be the first to review “Tomey OA-2000 Optical Biometer”

Your email address will not be published. Required fields are marked *